Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.015
Filtrar
1.
J Environ Sci (China) ; 142: 103-114, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38527876

RESUMO

This study investigated degradation behaviors of a nonsteroidal anti-inflammatory drug Nabumetone (NMT) and its major metabolite 6-methoxy-2-naphthylacetic acid (MNA) in the coupling process of ultraviolet and monochloramine (UV/NH2Cl). The second-order rate constants of the contaminants reacting with reactive radicals (HO•, Cl•, Cl2•⁻, and CO3•⁻) were determined by laser flash photolysis experiments. HO• and Cl• contributed predominantly with 52.3% and 21.7% for NMT degradation and 60.8% and 22.3% for MNA degradation. The presence of chlorides retarded the degradation of NMT, while promoted the destruction of MNA, which was ascribed to the photosensitization effects of MNA under UV irradiation. Density functional theory (DFT) calculations revealed that radical adduct formation (RAF) was dominant pathway for both HO• and Cl• reacting with the contaminants, and hydrogen atom transfer (HAT) preferred to occur on side chains of NMT and MNA. NMT reacted with NO2• through single electron transfer (SET) with the second-order rate constant calculated to be 5.35 × 107 (mol/L)-1 sec-1, and the contribution of NO2• was predicted to be 13.0% of the total rate constant of NMT in pure water, which indicated that NO2• played a non-negligible role in the degradation of NMT. The acute toxicity and developmental toxicity of NMT were enhanced after UV/NH2Cl treatment, while those of MNA were alleviated. The transformation products of both NMT and MNA exhibited higher mutagenicity than their parent compounds. This study provides a deep understanding of the mechanism of radical degradation of NMT and MNA in the treatment of UV/NH2Cl.


Assuntos
Cloraminas , Poluentes Químicos da Água , Purificação da Água , Nabumetona , Dióxido de Nitrogênio , Poluentes Químicos da Água/análise , Cinética , Raios Ultravioleta , Oxirredução , Modelos Teóricos , Cloro
2.
Water Res ; 254: 121409, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461602

RESUMO

Chloramine is the second most popular disinfectant and is widely used in the disinfection of drinking water. For chloramine disinfection, some standards require the total chlorine concentration to be maintained in an appropriate range in the water distribution system. Therefore, exploring the mechanism of chloramine decay and deriving an accurate chloramine decay model helps to optimize the disinfection process and ensure water quality safety. This paper proposed a locally enhanced mixed-order(LEM) model consisting of the first order model and the mixed order model to describe chloramine auto-decomposition and decays caused by other reactions respectively. Via proving the parameter a and k2 related to temperatures instead of initial chloramine concentration, the model had been further simplified. Nine chloramine decay experiments with different initial chloramine concentrations and temperatures were designed and carried out to evaluate the new model performance for chloramine decay simulation. The research results showed that the simplified LEM model could simulate the whole process of chloramine decay well. Its accuracy evaluation indexes (R2 and SSE) were better than that obtained from the first order model and the mixed order model. This paper proposed a simple and accurate method to simulate the process of chloramine decay and had a guiding significance for water quality safety assurance.


Assuntos
Desinfetantes , Água Potável , Purificação da Água , Cloraminas , Desinfecção/métodos , Purificação da Água/métodos , Cloro
3.
Water Res ; 254: 121433, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461603

RESUMO

Knowledge of the speciation of chlorine and chloramines in reverse osmosis (RO) permeate is needed to estimate the performance (i.e., pollutant log reduction) of subsequent UV/chlorine advanced oxidation processes (AOPs). To accurately predict the speciation, a previously reported breakpoint chlorination kinetic model was experimentally validated for pH 5.5 and reaction times < 3 min and used to predict the kinetics of breakpoint chlorination in RO permeate. The predictions showed that eliminating chloramines by adding chlorine at a dose beyond the chlorine-to-nitrogen (Cl/N) breakpoint ratio is not practical due to the high breakpoint Cl/N ratio for RO permeate (∼3.0 molar ratio) and an estimated > 40 min reaction time. The conversion from monochloramine (NH2Cl) to dichloramine (NHCl2) is the major process involved, and either or both free chlorine and chloramines may be the major species present, depending on the Cl/N ratio. Model simulations showed that increasing the oxidant dose may not always enhance the performance of UV/chlor(am)ine in RO permeate, due to the need for a low free chlorine dose for optimal •OH exposure in RO permeate. Further UV/AOPs modelling showed that it is important to control the NH2Cl concentration to improve the UV/AOP performance in RO permeate, which may be achieved by extending the reaction time after chlorine is added or increasing the applied Cl/N ratio (e.g., increasing chlorine dose). However, these measures only enhance the pollutant percentage removal by about 5 % under the conditions modelled. A simulation tool was developed and is provided to predict the speciation of chlor(am)ine in RO permeate.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Cloro , Cloraminas , Raios Ultravioleta , Oxirredução , Nitrogênio , Osmose
4.
Water Res ; 254: 121432, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461606

RESUMO

Chloramination is an effective strategy for eliminating pathogens from drinking water and repressing their regrowth in water distribution systems. However, the inevitable release of NH4+ potentially promotes nitrification and associated ammonia-oxidizing bacteria (AOB) contamination. In this study, AOB (Nitrosomona eutropha) were isolated from environmental water and treated with two disinfection stages (chloramine disinfection and chloramine residues) to investigate the occurrence mechanisms of AOB in chloramination. The results showed that N. eutropha had considerable resistance to monochloramine compared to Escherichia coli, whose inactivation rate constant was 19.4-fold lower. The higher resistance was attributed to high levels of extracellular polymer substances (EPS) in AOB, which contribute to AOB surviving disinfection and entering the distribution system. In AOB response to the chloramine residues stage, the respiratory activity of N. eutropha remained at a high level after three days of continuous exposure to high chloramine residue concentrations (0.5-1.5 mg/L). Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) suggested that the mechanism of N. eutropha tolerance involved a significantly high expression of the intracellular oxidative stress-regulating (sodB, txrA) and protein-related (NE1545, NE1546) genes. Additionally, this process enhanced EPS secretion and promoted biofilm formation. Adhesion predictions based on the XDLVO theory corroborated the trend of biofilm formation. Overall, the naturally higher resistance contributed to the survival of AOB in primary disinfection; the enhanced antioxidant response of surviving N. eutropha accompanied by biofilm formation was responsible for their increased resistance to the residual chloramines.


Assuntos
Água Potável , Purificação da Água , Antioxidantes , Abastecimento de Água , Purificação da Água/métodos , Cloraminas/química , Desinfecção/métodos , Biofilmes , Amônia/metabolismo
5.
Chemosphere ; 354: 141709, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484992

RESUMO

This paper highlights the potential to effectively inhibit nitrification and restore chloramine levels using a low copper concentration in a biofilm-affected (surface-to-volume ratio 16 m-1) continuous-flow laboratory-scale chloraminated system. High nitrite and low chloramine containing tanks are always recovered with chlorine "burn" by water utilities. The "burn" is not only costly and operationally complex, but also compromises the water quality, public health, and customer relations. A laboratory system comprising five reactors connected in series was operated. Each reactor simulated conditions typically encountered in full-scale systems. Low amount of copper (0.1-0.2 mg-Cu L-1) was dosed once per day into nitrified reactors. At any given time, only one reactor was dosed with copper. Not only inhibition of nitrification, chloramine decay associated with bulk water, biofilm and sediments also improved. However, the improvement was quicker and more significant when the influent to the reactor contained a high chloramine and a low nitrite concentration. Ammonia oxidising microbes exhibited resilience when exposed to low copper and chloramine concentrations for an extended period. Chloramine decay due to planktonic microbes and chemical reactions in bulk water decreased more rapidly than decay attributed to biofilm and sediments. The concept "biostable residual chlorine" explained how copper and chloramine can inhibit nitrification. Once nitrification was inhibited, the chloramine supplied from upstream effectively continued to suppress downstream nitrification, and this effect lasted more than 50 days even at 22 °C. The findings could be used to develop short-term copper dosing strategies and prevent negative impacts of nitrification and breakpoint chlorination.


Assuntos
Cloraminas , Cobre , Cloro , Nitritos , Amônia , Biofilmes , Nitrificação , Reatores Biológicos
6.
J Hazard Mater ; 469: 134075, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38508114

RESUMO

Chlorine-resistant bacteria (CRB) in drinking water treatment plants (DWTPs) jeopardize water quality and pose a potential risk to human health. However, the specific response of CRB to chlorination and chloramination remains uncharacterized. Therefore, we analyzed 16 S rRNA sequencing data from water samples before and after chlorination and chloramination taken between January and December 2020. Proteobacteria and Firmicutes dominated all finished water samples. After chloramination, Acinetobacter, Pseudomonas, Methylobacterium, Ralstonia, and Sphingomonas were the dominant CRB, whereas Ralstonia, Bacillus, Acinetobacter, Pseudomonas, and Enterococcus were prevalent after chlorination. Over 75% of the CRB e.g. Acinetobacter, Pseudomonas, Bacillus, and Enterococcus were shared between the chlorination and chloramination, involving potentially pathogens, such as Acinetobacter baumannii and Pseudomonas aeruginosa. Notably, certain genera such as Faecalibacterium, Geobacter, and Megasphaera were enriched as strong CRB after chloramination, whereas Vogesella, Flavobacterium, Thalassolituus, Pseudoalteromonas, and others were enriched after chlorination according to LEfSe analysis. The shared CRB correlated with temperature, pH, and turbidity, displaying a seasonal pattern with varying sensitivity to chlorination and chloramination in cold and warm seasons. These findings enhance our knowledge of the drinking water microbiome and microbial health risks, thus enabling better infectious disease control through enhanced disinfection strategies in DWTPs.


Assuntos
Bacillus , Desinfetantes , Água Potável , Poluentes Químicos da Água , Purificação da Água , Humanos , Cloro/química , Halogenação , Halogênios , Desinfecção , Flavobacterium , Cloraminas/química
7.
J Toxicol Sci ; 49(3): 95-103, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38432956

RESUMO

This study was conducted as part of an investigation into the cause of vesnarinone-associated agranulocytosis. When HL-60 cells were exposed to vesnarinone for 48 hr, little cytotoxicity was observed, although reduced glutathione (GSH) content decreased in a concentration-dependent manner. Significant cytotoxicity and reactive oxygen species (ROS) production were observed when intracellular GSH content was reduced by treatment with L-buthionine-(S, R)-sulphoximine. The involvement of myeloperoxidase (MPO) metabolism was suggested, as when HL-60 cells were exposed to a reaction mixture of vesnarinone-MPO/H2O2/Cl-, cytotoxicity was also observed. In contrast, the presence of GSH (1 mM) protected against these cytotoxic effects. Liquid chromatography-mass spectrometry analysis of the MPO/H2O2/Cl- reaction mixture revealed that vesnarinone was converted into two metabolites, (4-(3,4-dimethoxybenzoyl)piperazine [Metabolite 1: M1] and 1-chloro-4-(3,4-dimethoxybenzoyl)piperazine [Metabolite 2: M2]). M2 was identified as the N-chloramine form, a reactive metabolite of M1. Interestingly, M2 was converted to M1, which was accompanied by the conversion of GSH to oxidized GSH (GSSG). Furthermore, when HL-60 cells were exposed to synthetic M1 and M2 for 24 hr, M2 caused dose-dependent cytotoxicity, whereas M1 did not. Cells were protected from M2-derived cytotoxicity by the presence of GSH. In conclusion, we present the first demonstration of the cytotoxic effects and ROS production resulting from the MPO/H2O2/Cl- metabolic reaction of vesnarinone and newly identified the causative metabolite, M2, as the N-chloramine metabolite of M1, which induces cytotoxicity in HL-60 cells. Moreover, a protective role of GSH against the cytotoxicity was revealed. These findings suggest a possible nonimmunological cause of vesnarinone agranulocytosis.


Assuntos
Agranulocitose , Antineoplásicos , Pirazinas , Quinolinas , Humanos , Cloraminas , Glutationa , Células HL-60 , Peróxido de Hidrogênio/toxicidade , Espécies Reativas de Oxigênio , Agranulocitose/induzido quimicamente , Cloretos , Piperazinas
8.
Water Res ; 253: 121331, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38377929

RESUMO

In practical drinking water treatment, chlorine and chloramine disinfection exhibit different mechanisms that affect biofilm growth. This study focused on the influence of biofilm composition changes, especially extracellular polymeric substance (EPS) fractions, on the potential formation and toxicity of nitrogenous disinfection by-products (N-DBP). Significant differences in microbial diversity and community structure were observed between the chlorine and chloramine treatments. Notably, the biofilms from the chloramine-treated group had higher microbial dominance and greater accumulation of organic precursors, as evidenced by the semi-quantitative confocal laser-scanning microscopy assay of more concentrated microbial aggregates and polysaccharide proteins in the samples. Additionally, the chloramine-treated group compared with chlorine had a higher EPS matrix content, with a 13.5 % increase in protein. Furthermore, the protein distribution within the biofilm differed; in the chlorine group, proteins were concentrated in the central region, whereas in the chloramine group, proteins were primarily located at the water-biofilm interface. Notably, functional prediction analyses of protein fractions in biofilms revealed specific functional regulation patterns and increased metabolism-related abundance of proteins in the chlorine-treated group. This increase was particularly pronounced for proteins such as dehydrogenases, reductases, transcription factors, and acyl-CoA dehydrogenases. By combining the Fukui function and density functional calculations to further analyse the effect of biofilm component changes on N-DBP production under chlorine/chloramine and by assessing the toxicity risk potential of N-DBP, it was determined that chloramine disinfection is detrimental to biofilm control and the accumulation of protein precursors has a higher formation potential of N-DBPs and toxicity risk, increasing the health risk of drinking water.


Assuntos
Desinfetantes , Água Potável , Poluentes Químicos da Água , Purificação da Água , Desinfecção , Cloraminas , Cloro/química , Água Potável/análise , Matriz Extracelular de Substâncias Poliméricas/química , Nitrogênio/análise , Biofilmes , Desinfetantes/análise , Poluentes Químicos da Água/análise , Halogenação
9.
Water Res ; 253: 121302, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38401474

RESUMO

With the increasing discharge of wastewater effluent to natural waters, there is an urgent need to achieve both pathogenic microorganism inactivation and the mitigation of disinfection by-products (DBPs) during disinfection. Studies have shown that two-step chlorination, which injected chlorine disinfectant by splitting into two portions, was more effective in inactivating Escherichia coli than one-step chlorination under same total chlorine consumption and contact time. In this study, we observed a substantial reduction in the formation of five classes of CX3R-type DBPs, especially highly toxic haloacetonitriles (HANs), during two-step chlorination of secondary effluent when the mass ratio of chlorine-to-nitrogen exceeded 2. The shift of different chlorine species (free chlorine, monochloramine and organic chloramine) verified the decomposition of organic chloramines into monochloramine during second chlorination stage. Notably, the organic chloramines generated from the low molecular weight (< 1 kDa) fraction of dissolved organic nitrogen in effluent organic matter tended to decompose during the second step chlorination leading to the mitigation of HAN formation. Furthermore, the microbiological analysis showed that two-step chlorinated effluent had a slightly lower ecological impact on surface water compared to one-step chlorination. This work provided more information about the two-step chlorination for secondary effluent, especially in terms of organic chloramine transformation and HAN control.


Assuntos
Desinfetantes , Poluentes Químicos da Água , Purificação da Água , Cloraminas , Desinfecção , Esgotos , Halogenação , Cloro/análise , Peso Molecular , Poluentes Químicos da Água/análise
10.
Chemosphere ; 353: 141536, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38423150

RESUMO

Chloramination was commonly used as disinfectant for killing pathogens in water. However, in this process, nitrogen-containing disinfection by-products (N-DBPs) would accidently form and subsequently rise toxicity. Here, we investigated acute toxicity variation and by-products formation during chloramination treatment on UV filter 2-hydroxy-4-methoxy-5-sulfonic acid benzophenone (BP-4). Under alkaline conditions, the acute toxicity of this system had significant increase. A total of 17 transformation products were tentatively identified, and for them, plausible transformation pathways were proposed. Noticeably, numerous aniline and nitrosobenzene analogs were detected, and the dramatic increase of acute toxicity in this system might be primarily attributed to the formation of benzoquinone and aniline analogs. Besides, bromophenol, iodophenol and iodobenzoquinone analogs exhibiting high toxicity were generated in the presence of bromine and iodide ions. This study indicates that chloramination treatment may significantly increase potential health risk, further management on disinfection system is reasonable.


Assuntos
Desinfetantes , Poluentes Químicos da Água , Purificação da Água , Desinfecção , Cloraminas , Nitrogênio , Halogenação , Poluentes Químicos da Água/análise , Compostos de Anilina , Cloro
11.
Chemosphere ; 352: 141312, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38311043

RESUMO

Algal blooms worldwide pose many challenges to drinking water production. Pre-oxidation with NaClO, KMnO4, or ozone is commonly used to enhance algal removal in conventional drinking water treatment processes. However, these currently utilized oxidation methods often result in significant algal cell lysis or impede the operation of the subsequent units. Higher algal removal with pre-chlorination in algal solutions prepared with natural water, compared to those prepared with ultrapure water, has been observed. In the present studies, preliminary findings indicate that ammonium in natural water alters chlorine species to NH2Cl, leading to improved treatment efficiency. NH2Cl with 1.5-3.0 mg∙L-1 as Cl2 with an oxidation time of 3-7 h significantly enhancing algal removal by coagulation. The selective oxidation of surface-absorbed organic matter (S-AOM) by NH2Cl, followed by the subsequent peeling off of this material from the algal surface, leading to an increase in zeta potential from -20.2 mV to -3.8 mV, constitutes the primary mechanism of enhanced algal removal through coagulation. These peeled S-AOM retained their large molecular weight and acted as polymer aids. Compared with NaClO and KMnO4, NH2Cl displays the best performance in improving algal removal, avoiding cell lysis, and decreasing the potential for nitrogenous disinfection byproducts formation under the reaction conditions used in this study. Notably, in major Chinese cities, water purification plants commonly rely on suburban lakes or reservoirs as water sources, necessitating the transportation of raw water over long distances for times up to several hours. These conditions favor the implementation of NH2Cl pre-oxidation. The collective results indicate the potential of NH2Cl oxidation as a viable pretreatment strategy for algal contamination during water treatment processes.


Assuntos
Água Potável , Poluentes Químicos da Água , Purificação da Água , Cloraminas , Desinfecção , Cloro , Halogenação , Purificação da Água/métodos , Poluentes Químicos da Água/análise
12.
Water Res ; 251: 121098, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38219686

RESUMO

Manual flushing of building plumbing is commonly used to address water quality issues that arise from water stagnation. Autonomous flushing informed by sensors has the potential to aid in the management of building plumbing, but a number of knowledge gaps hinder its application. This study evaluates autonomous flushing of building plumbing with online sensor and actuator nodes deployed under kitchen sinks in five residential houses. Online oxidation-reduction potential (ORP) and temperature data were collected for nine weeks during the winter and summer in houses with both free chlorine and chloramine. ORP levels in houses with free chlorine residuals decreased after overnight stagnation. The overnight decrease in ORP was not observed when tap water was automatically flushed for five minutes at 6:00 h every morning. ORP levels in houses with chloramine residuals did not decrease consistently after overnight stagnation, and daily automated flushes did not have an observable effect on the ORP signals. Additional laboratory experiments were carried out to evaluate ORP signals during chlorine decay and after incremental changes in chlorine, as would be expected in building plumbing conditions. Results from the lab and field deployments suggest on-line ORP sensors may be used to detect free chlorine decay due to stagnating water, but are not as effective in detecting chloramine decay. However, field results also suggest ORP may not respond as expected on a timely manner after free chlorine or chloramine have been restored, hindering their applicability in developing control algorithms. In this paper we tested twice-daily five-minute automatic flushing and found that it counteracts water quality degradation associated with overnight stagnation in free chlorine systems. An automatic sensor-based flushing is proposed using online temperature sensor data to determine when flushing has reached water from the main. The results suggest that flushing informed by temperature sensors can reduce the flushing time by 46 % compared to the preset five-minute static flush.


Assuntos
Água Potável , Engenharia Sanitária , Abastecimento de Água , Cloraminas , Cloro , Temperatura , Oxirredução
13.
Environ Sci Technol ; 58(4): 2048-2057, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38238190

RESUMO

In drinking water chloramination, monochloramine autodecomposition occurs in the presence of excess free ammonia through dichloramine, the decay of which was implicated in N-nitrosodimethylamine (NDMA) formation by (i) dichloramine hydrolysis to nitroxyl which reacts with itself to nitrous oxide (N2O), (ii) nitroxyl reaction with dissolved oxygen (DO) to peroxynitrite or mono/dichloramine to nitrogen gas (N2), and (iii) peroxynitrite reaction with total dimethylamine (TOTDMA) to NDMA or decomposition to nitrite/nitrate. Here, the yields of nitrogen and oxygen-containing end-products were quantified at pH 9 from NHCl2 decomposition at 200, 400, or 800 µeq Cl2·L-1 with and without 10 µM-N TOTDMA under ambient DO (∼500 µM-O) and, to limit peroxynitrite formation, low DO (≤40 µM-O). Without TOTDMA, the sum of free ammonia, monochloramine, dichloramine, N2, N2O, nitrite, and nitrate indicated nitrogen recoveries ±95% confidence intervals were not significantly different under ambient (90 ± 6%) and low (93 ± 7%) DO. With TOTDMA, nitrogen recoveries were less under ambient (82 ± 5%) than low (97 ± 7%) DO. Oxygen recoveries under ambient DO were 88-97%, and the so-called unidentified product of dichloramine decomposition formed at about three-fold greater concentration under ambient compared to low DO, like NDMA, consistent with a DO limitation. Unidentified product formation stemmed from peroxynitrite decomposition products reacting with mono/dichloramine. For a 2:2:1 nitrogen/oxygen/chlorine atom ratio and its estimated molar absorptivity, unidentified product inclusion with uncertainty may close oxygen recoveries and increase nitrogen recoveries to 98% (ambient DO) and 100% (low DO).


Assuntos
Óxidos de Nitrogênio , Oxigênio , Purificação da Água , Nitrogênio , Nitritos/química , Nitratos/química , Amônia/química , Espécies Reativas de Nitrogênio , Ácido Peroxinitroso , Cloraminas/química , Dimetilnitrosamina/química
14.
Molecules ; 29(2)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38257310

RESUMO

The unrestricted utilization of antibiotics poses a critical challenge to global public health and safety. Levofloxacin (LEV) and sulfaphenazole (SPN), widely employed broad-spectrum antimicrobials, are frequently detected at the terminal stage of water treatment, raising concerns regarding their potential conversion into detrimental disinfection byproducts (DBPs). However, current knowledge is deficient in identifying the potential DBPs and elucidating the precise transformation pathways and influencing factors during the chloramine disinfection process of these two antibiotics. This study conducts a comprehensive analysis of reaction pathways, encompassing piperazine ring opening/oxidation, Cl-substitution, OH-substitution, desulfurization, and S-N bond cleavage, during chloramine disinfection. Twelve new DBPs were identified in this study, exhibiting stability and persistence even after 24 h of disinfection. Additionally, an examination of DBP generation under varying disinfectant concentrations and pH values revealed peak levels at a molar ratio of 25 for LEV and SPN to chloramine, with LEV contributing 11.5% and SPN 23.8% to the relative abundance of DBPs. Remarkably, this research underscores a substantial increase in DBP formation within the molar ratio range of 1:1 to 1:10 compared to 1:10 to 1:25. Furthermore, a pronounced elevation in DBP generation was observed in the pH range of 7 to 8. These findings present critical insights into the impact of the disinfection process on these antibiotics, emphasizing the innovation and significance of this research in assessing associated health risks.


Assuntos
Levofloxacino , Purificação da Água , Levofloxacino/farmacologia , Sulfafenazol , Cloraminas/farmacologia , Desinfecção , Antibacterianos/farmacologia
15.
J Hazard Mater ; 465: 132985, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38000285

RESUMO

The increasing demand for dairy products has led to the production of a large amount of wastewater in dairy plants, and disinfection is an essential treatment process before wastewater discharge. Disinfection byproducts (DBPs) in disinfected dairy wastewater may negatively influence the aquatic organisms in receiving water. During chlorine and chloramine disinfection of dairy wastewater, the concentrations of aliphatic DBPs increased from below the detection limits to 485.1 µg/L and 26.6 µg/L, respectively. Brominated and iodinated phenolic DBPs produced during chlor(am)ination could further react with chlorine/chloramine to be transformed. High level of bromide in dairy wastewater (12.9 mg/L) could be oxidized to active bromine species by chlorine/chloramine, promoting the formation of highly toxic brominated DBPs (Br-DBPs), and they accounted for 80.3% and 71.1% of the total content of DBPs in chlorinated and chloraminated dairy wastewater, respectively. Moreover, Br-DBPs contributed 49.9-75.9% and 34.2-96.4% to the cumulative risk quotient of DBPs in chlorinated and chloraminated wastewater, respectively. The cumulative risk quotient of DBPs on green algae, daphnid, and fish in chlorinated wastewater was 2.8-11.4 times higher than that in chloraminated wastewater. Shortening disinfection time or adopting chloramine disinfection can reduce the ecological risks of DBPs.


Assuntos
Desinfetantes , Poluentes Químicos da Água , Purificação da Água , Animais , Desinfecção , Cloraminas , Águas Residuárias , Cloro , Halogenação , Poluentes Químicos da Água/análise
16.
Environ Pollut ; 341: 122902, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37949160

RESUMO

Booster disinfection was often applied to control the microorganism's growth in long-distance water supply systems. The effect of booster disinfection on the changing patterns of antibiotic resistance and bacterial community was investigated by a simulated water distribution system (SWDS). The results showed that the antibiotic resistance bacteria (ARB) and antibiotic resistance genes (ARGs) were initially removed after dosing disinfectants (chlorine and chloramine), but then increased with the increasing water age. However, the relative abundance of ARGs significantly increased after booster disinfection both in buck water and biofilm, then decreased along the pipeline. The pipe materials and disinfectant type also affected the antibiotic resistance. Chlorine was more efficient in controlling microbes and ARGs than chloramine. Compared with UPVC and PE pipes, SS pipes had the lowest total bacteria, ARB concentration, and ARB percentage, mainly due to higher disinfectant residuals and a smoother surface. The significant correlation (rs = 0.77, p < 0.001) of the 16S rRNA genes was observed between buck water and biofilm, while the correlations of targeted ARGs were found to be weak. Bray-Curtis similarity index indicated that booster disinfection significantly changed the biofilm bacterial community and the disinfectant type also had a marked impact on the bacterial community. At the genus level, the relative abundance of Pseudomonas, Sphingomonas, and Methylobacterium significantly increased after booster disinfection. Mycobacterium increased after chloramination while decreased after chlorination, indicating Mycobacterium might resist chloramine. Pseudomonas, Methylobacterium, and Phreatobacter were found to correlate well with the relative abundance of ARGs. These results highlighted antibiotic resistance shift and bacterial community alteration after booster disinfection, which may be helpful in controlling potential microbial risk in drinking water.


Assuntos
Desinfetantes , Água Potável , Purificação da Água , Água Potável/microbiologia , Desinfecção/métodos , Cloraminas/farmacologia , Cloro/farmacologia , Cloro/análise , Prevalência , RNA Ribossômico 16S , Antagonistas de Receptores de Angiotensina/farmacologia , Purificação da Água/métodos , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Desinfetantes/farmacologia , Desinfetantes/análise , Bactérias , Antibacterianos/farmacologia , Resistência Microbiana a Medicamentos , Genes Bacterianos
17.
Water Res ; 249: 120958, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38064782

RESUMO

Drinking water distribution systems (DWDSs) are important for supplying high-quality water to consumers and disinfectant is widely used to control microbial regrowth in DWDSs. However, the disinfectant's influences on microbial community and antibiotic resistome in DWDS biofilms and the underlying mechanisms driving their dynamics remain elusive. The study investigated the effects of chlorine and chloramine disinfection on the microbiome and antibiotic resistome of biofilms in bench-scale DWDSs using metagenomics assembly. Additionally, the biofilm activity and viability were monitored based on adenosine triphosphate (ATP) and flow cytometer (FCM) staining. The results showed that both chlorine and chloramine disinfectants decreased biofilm ATP, although chloramine at a lower dosage (1 mg/L) could increase it. Chloramine caused a greater decrease in living cells than chlorine. Furthermore, the disinfectants significantly lowered the microbial community diversity and altered microbial community structure. Certain bacterial taxa were enriched, such as Mycobacterium, Sphingomonas, Sphingopyxis, Azospira, and Dechloromonas. Pseudomonas aeruginosa exhibited high resistance towards disinfectants. The disinfectants also decreased the complexity of microbial community networks. Some functional taxa (e.g., Nitrospira, Nitrobacter, Nitrosomonas) were identified as keystones in chloramine-treated DWDS microbial ecological networks. Stochasticity drove biofilm microbial community assembly, and disinfectants increased the contributions of stochastic processes. Chlorine had greater promotion effects on antibiotic resistance genes (ARGs), mobile genetic elements (MGEs) and ARG hosts than chloramine. The disinfectants also selected pathogens, such as Acinetobacter baumannii and Klebsiella pneumonia, and these pathogens also harbored ARGs and MGEs. Overall, this study provides new insights into the effects of disinfectants on biofilm microbiome and antibiotic resistome, highlighting the importance of monitoring and managing disinfection practices in DWDSs.


Assuntos
Desinfetantes , Água Potável , Microbiota , Purificação da Água , Desinfetantes/farmacologia , Água Potável/química , Cloraminas/farmacologia , Cloro/farmacologia , Antibacterianos/farmacologia , Bactérias/genética , Biofilmes , Trifosfato de Adenosina
18.
J Hazard Mater ; 463: 132961, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-37951171

RESUMO

Amine-based pharmaceuticals are a significant class of N-nitrosodimethylamine (NDMA) precursors. This study investigated the use of unactivated peroxymonosulfate (PMS) to control amine-based pharmaceuticals and their NDMA formation potential. Kinetic analysis and product identification revealed that sumatriptan and doxylamine primarily underwent reactions at their tertiary amine group, while ranitidine and nizatidine had both tertiary amine and thioether group as reaction sites. The NDMA formation from sumatriptan and doxylamine during post-chloramination was significantly reduced with the abatement of the parent contaminants, while the formation of NDMA remained high even if full abatement of ranitidine and nizatidine was achieved. Product formation kinetics and reference standard tests revealed the great contribution of transformation products to NDMA formation. Ranitidine could be oxidized to sulfoxide-type product ranitidine-SO and N-oxide type product ranitidine-NO. Ranitidine-SO exhibited a high NDMA yield comparable to that of ranitidine (>90%), while ranitidine-NO showed a low NDMA yield (2%). With further oxidation of ranitidine-SO at the tertiary amine group, NDMA formation was reduced by more than 90%. The underlying mechanism for the importance of the tertiary amine group in NDMA formation was demonstrated by quantum chemical calculation. These findings underscore the potential of PMS pre-oxidation on NDMA control.


Assuntos
Poluentes Químicos da Água , Purificação da Água , Aminas , Ranitidina , Cloraminas , Dimetilnitrosamina/análise , Sumatriptana/análise , Cinética , Nizatidina/análise , Doxilamina/análise , Preparações Farmacêuticas , Poluentes Químicos da Água/análise
19.
Water Res ; 248: 120858, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37988808

RESUMO

Many factors, including microbiome structure and activity in the drinking water distribution system (DWDS), affect the colonization potential of opportunistic pathogens. The present study aims to describe the dynamics of active bacterial communities in DWDS and identify the factors that shape the community structures and activity in the selected DWDSs. Large-volume drinking water and hot water, biofilm, and water meter deposit samples were collected from five DWDSs. Total nucleic acids were extracted, and RNA was further purified and transcribed into its cDNA from a total of 181 water and biofilm samples originating from the DWDS of two surface water supplies (disinfected with UV and chlorine), two artificially recharged groundwater supplies (non-disinfected), and a groundwater supply (disinfected with UV and chlorine). In chlorinated DWDSs, concentrations of <0.02-0.97 mg/l free chlorine were measured. Bacterial communities in the RNA and DNA fractions were analysed using Illumina MiSeq sequencing with primer pair 341F-785R targeted to the 16S rRNA gene. The sequence libraries were analysed using QIIME pipeline, Program R, and MicrobiomeAnalyst. Not all bacterial cells were active based on their 16S rRNA content, and species richness was lower in the RNA fraction (Chao1 mean value 490) than in the DNA fraction (710). Species richness was higher in the two DWDSs distributing non-disinfected artificial groundwater (Chao1 mean values of 990 and 1 000) as compared to the two disinfected DWDSs using surface water (Chao1 mean values 190 and 460) and disinfected DWDS using ground water as source water (170). The difference in community structures between non-disinfected and disinfected water was clear in the beta-diversity analysis. Distance from the waterworks also affected the beta diversity of community structures, especially in disinfected distribution systems. The two most abundant bacteria in the active part of the community (RNA) and total bacterial community (DNA) belonged to the classes Alphaproteobacteria (RNA 28 %, DNA 44 %) and Gammaproteobacteria (RNA 32 %, DNA 30 %). The third most abundant and active bacteria class was Vampirovibrionia (RNA 15 %), whereas in the total community it was Paceibacteria (DNA 11 %). Class Nitrospiria was more abundant and active in both cold and hot water in DWDS that used chloramine disinfection compared to non-chlorinated or chlorine-using DWDSs. Thirty-eight operational taxonomic units (OTU) of Legionella, 30 of Mycobacterium, and 10 of Pseudomonas were detected among the sequences. The (RT)-qPCR confirmed the presence of opportunistic pathogens in the DWDSs studied as Legionella spp. was detected in 85 % (mean value 4.5 × 104 gene copies/100 ml), Mycobacterium spp. in 95 % (mean value 8.3 × 106 gene copies/100 ml), and Pseudomonas spp. in 78 % (mean value 1.6 × 105 gene copies/100 ml) of the water and biofilm samples. Sampling point inside the system (distance from the waterworks and cold/hot system) affected the active bacterial community composition. Chloramine as a chlorination method resulted in a recognizable community composition, with high abundance of bacteria that benefit from the excess presence of nitrogen. The results presented here confirm that each DWDS is unique and that opportunistic pathogens are present even in conditions when water quality is considered excellent.


Assuntos
Cloraminas , Água Potável , Água Potável/análise , Cloro/análise , Finlândia , RNA Ribossômico 16S/genética , Abastecimento de Água , Bactérias/genética , DNA , Biofilmes , Microbiologia da Água
20.
PeerJ ; 11: e16452, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38077413

RESUMO

Background: Chloramine-T (CL-T) is a synthetic sodium salt used as a disinfectant in fish farms to combat bacterial infections in fish gills and skin. While its efficacy in pathogen control is well-established, its reactivity with various functional groups has raised concerns. However, limited research exists on the toxicity of disinfection by-products to aquatic organisms. Therefore, this study aims to assess the sublethal effects of CL-T on adult zebrafish by examining biomarkers of nucleus cytotoxicity and genotoxicity, acetylcholinesterase (AChE) inhibition, and histopathological changes. Methods: Male and female adult zebrafish (wildtype AB lineage) specimens were exposed to 70, 140, and 200 mg/L of CL-T and evaluated after 96 h. Cytotoxic and genotoxic effects were evaluated by estimating the frequencies of nuclear abnormalities (NA), micronuclei (MN), and integrated optical density (IOD) of nuclear erythrocytes. Histopathological changes in the gills and liver were assessed using the degree of tissue changes (DTC). AChE activity was measured in brain samples. Results and conclusions: At a concentration of 200 mg/L, NA increased, indicating the cytogenotoxic potential of CL-T in adult zebrafish. Morphological alterations in the nuclei were observed at both 70 and 200 mg/L concentrations. Distinct IOD profiles were identified across the three concentrations. There were no changes in AChE activity in adult zebrafish. The DTC scores were high in all concentrations, and histological alterations suggested low to moderate toxicity of CL-T for adult zebrafish.


Assuntos
Perciformes , Peixe-Zebra , Animais , Masculino , Feminino , Acetilcolinesterase , Cloraminas/toxicidade , Compostos de Tosil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...